When using a single electrode solid warp stop motions,
the motions are fixed to the bracket, and a warp stop
plate must be installed underneath the motions, which
is covered with a thin metal plate, which is connected
to the warp stop conductor. When the warp stop sheet
do not touch the warp stop motions, the loom operates
normally. When the warp breaks, the drop wire falls
down and contacts the drop wire plate, causing the warp
stop circuit to conduct and the weaving machine to stop.