The warp stop motions are fixed to the bracket which
is insulated from the machine body. The core plate of
the motions is connected to the warp stop conductor
(12V low voltage conductor). The warp stop motions
are connected to the warp stop wires (12V low voltage
wires). When the core plate of the warp stop motions
is not in contact with the warp stop motions, the loom
rotates normally. When the warp breaks, the drop wire
falls down, and then the drop wire contacts the core
plate of the warp stop bar, causing the warp stop circuit
to conduct, causing the magnetic starter motor to stop,
and the weaving machine to stop.